Difficulty: novice
Content
Learning Objectives
After reading this article, you’ll be able to:
- Prepare your environment to start using Airthings
- Install Airthings
- Verify correct installation of Airthings
Airthings comfort sensors gather data on Humidity + CO2 + Temperature.
Find here the checklist for installation: Checklist hardware on-site visit/installation.
Prerequisite: Gateway
Airthings connect to their own proprietary hub. Make sure you install your Airthings hub before installing the sensors (check out Airthings gateway installation for more information).
Hardware & Network Requirements
For Airthings hub to connect to the cloud, there is no need for ports to be opened on the network.
Unboxing
Sensor Installation
Set up Airthings devices
Good to know
- A Smartlink will be established between a powered-up sensor device and a nearby powered-up Hub. It take 20 minutes to establish such Smartlink.
- It takes additionally 5 to 10 minutes for sensor data to be made available on Airthings dashboard. Allow for a couple of more minutes for the data to be send to the Workplace IoT Platform.
- Wave devices are upgraded seamlessly in the background and you do not need to take any action in this process. Such upgrade can take up to 120 minutes for large installations.
- Allow 7 days after deployment for data (self) calibration of indoor air quality sensors such as Radon, TVOC and CO2
Mount devices
Once the sensor device is confirmed in good radio range to the Hub, you can permanently mount the device.
- wall-mount the device 150-170 cm above the floor
- mount the device at least 1 m away from exterior walls, doors, air supply/exhausts, mechanical fans, heaters or any other significant source of heat or cold
- do not mount Wave devices on the ceiling
Use the included double-sided tape for temporary installations. For permanent installations we recommend using a screw to wall-mount. Ensure that the device cannot fall onto someone or something and cause damage.
Airthings nor Spacewell do not take responsibility for improperly installed sensor devices.
Deploy sensors in Airthings Platform
Ask your Spacewell Implementation Consultant to configure Airthings sensors on Airthings Platform (SW internal).
Deploy sensors in Workplace Platform
On the back panel of the sensor, you will find the Device ID (format 293002XXXX). This is the ID to use to assign the device to your tenant and do the location mapping in Studio.
Add New Device in Studio
- Go to your environment (https://studio.cobundu.com ) and log in
- Select the location, where you can manually add a sensor via "Add New Device"
Manually add device through location > devices > new: location is filled in.
Select Device Type "Airthings". This will automatically link the device channel.
Enter Device ID as serial-number with all capitals (format 293002XXXX).
Enter a meaningful Device Name (eg customer_floor number_area).
Select a Location from the location tree if this is already known (automatically filled in if location was selected before adding new device).
noteOnly applicable for Comfort sensors: Next to the already selected (main) Room or Workplace, you can visualize incoming comfort data on other, Linked Locations. Imagine having 1 comfort sensor in an open office space and you want to visualize this data on all 8 workplaces in that space: Linked Location needs to contain all 8 workplaces. (More information on Linked Locations: Live floorplan settings)
Only applicable for Comfort sensors: Next to the already selected (main) Room or Workplace, you can visualize incoming comfort data on other, Linked Locations. Imagine having 1 comfort sensor in an open office space and you want to visualize this data on all 8 workplaces in that space: Linked Location needs to contain all 8 workplaces. (More information on Linked Locations: Live floorplan settings)
Selecting the correct Device Type "Airthings" should automatically set the Sensor Types and Channels to "Temperature, Humidity, CO2, …" (see Advanced).